AVIAN THE POWERFUL VENTILATOR DESIGNED FOR INTER AND INTRA HOSPITAL TRANSPORT |
|
|
|
| FROM TRANSPORT | TO HOSPITAL BED |
![]() |
|
CONTROLS |
|
| Mode | Control, Assist/Control |
| SIMV/CPAP, OFF | |
| Breath Rate | 0 to 150 bpm |
| Flow | 5 to 100 lpm |
| Inspiratory Time | 0.1 to 3.0 sec. |
| Tidal Volume | 50 to 2000 ml |
| Assist Sensitivity | -2 to -8 cmH2O |
| Manual Breath | Single breath in accordance with current Flow and Inspiratory Time or Tidal Volume settings |
| PEEP/CPAP | 0 to 20 cmH2O (with removable PEEP valve) |
| Manual PEEP Reference | 0 to 20 cmH2O |
| Sigh | On/Off 1 Sigh / 100 breaths or 7
minutes. 1.5 x set Tidal Volume (2000 ml maximum) or 1.5 x set Inspiration Time (3.0
seconds maximum) In Sigh, High Pressure Limit 1.5 x set (100 cmH2O maximum) |
| Pressure Relief | 10 to 100 cmH2O |
MONITORS & INDICATORS |
|
| Green LED | Power On |
| Yellow LED | External Power |
| Red LED - (alarm conditions) | PEEP not set |
| Apnea | |
| Battery Low/Fail | |
| External Power Failure | |
| Vent Inoperative | |
| Disconnect | |
| 4-digit 7 Segment | Mean Airway Pressure (M.A.P.), |
| LED Display | vv 0 to 100 cmH2O |
| Peak Inspiratory Pressure (P.I.P.), | |
| vv 0 to 100 cmH2O | |
| Airway Pressure (Paw), | |
| vv 0 to 100 cmH2O | |
| Manual PEEP Ref. 0 to 20 cmH2O | |
| Inspiratory Time 0.1 to 3.0 seconds | |
| Tidal Volume 50 to 2000 ml | |
| Breath Rate 0 to 150 bpm | |
| Flow 5 to 100 lpm | |
| LED Bar Graph | Airway Pressure (Paw) |
| -10 to 100 cmH2O | |
ALARMS |
|
| High Peak Pressure | Baseline plus 1 cmH2O - 100 cmH2O |
| Low Peak Pressure | OFF, 2 to 50 cmH2O |
| I:E Ratio (Inverse) | Audible / Visual (LED) |
| Apnea | Audible / Visual (20 sec) |
| External Power Low / Fail | Audible / Visual |
| Disconnect | Audible / Visual |
| PEEP Not Set | Audible / Visual |
| Battery Low / Fail | Audible / Visual |
| Vent IN/OP | Audible / Visual |
| Alarm Silence / Reset | Variable Duration (depending on the alarm), single touch button |
ELECTRICAL REQUIREMENTS |
|
| External DC Power Source | Input Voltage 12 - 30 VDC |
| Internal Battery | 6-volt rechargeable sealed lead acid (11 hours minimum operation on full charge) |
| External AC Power Adapter | 100 - 125 VAC, 50-400 Hz |
| (Switch selectable input) | 200 - 250 VAC, 50-400 Hz |
PNEUMATIC REQUIREMENTS |
|
| 40 to 60 PSIG of clean, dry medical grade air, oxygen or air / oxygen mixtures |
Compressed gas cylinders Medical grade air compressors On-Board aircraft gas sources, Blended gas mixtures from a blender |
DIMENSIONS & WEIGHTS |
|
| Height | 10 inches |
| (254 mm) | |
| Width | 12 inches |
| (305 mm) | |
| Depth | 5 inches |
| (127 mm) | |
| Weight | 10.8 lbs. |
| (5.0 kg) | |
| Operating Temperatures | -4 °F to 115 °F |
| (-20 °C to 40 °C) | |
| Storage Temperatures | 50 °F to 80 °F |
| (10 °C to 27 °C) | |
ORDERING INFORMATION |
|
| 15345 | Avian Transport Ventilator System | |
| Includes: | ||
| P/N: | Description: | |
| 09184 | POWER CORD, U.S. | |
| 10290 | CARRYING CASE | |
| 10293 | HOSE ASSEMBLY O2 | |
| 10333 | PATIENT CIRCUIT KIT - (Reusable) | |
| 15365 | AVIAN VENTILATOR | |
| 15364 | DC INPUT CORD | |
| 68107 | POWER SUPPLY | |
| L1248 | OP/SERVICE MANUAL | |
| NOTES - | Disposable circuits
also available. International configurations also available. |
|
| 10333 | Patient Circuit Kit - (Reusable) | |
| Includes: | ||
| P/N: | Description: | |
| 10294 | TUBE ASSEMBLY, AIRWAY | |
| 10295 | TUBE ASSEMBLY, EXHALATION VALVE | |
| 20516 | TUBING, SMOOTH BORE | |
| 33687 | PEEP VALVE | |
| 33686 | EXHALATION VALVE | |
| Options and Accessories: | ||
| P/N: | Description: | |
| 04322 | 1" POLE MOUNT POST BRACKET | |
| 06446 | 1" X 50" CROOKED NECK POLE | |
| 07999 | STAND BASE | |
| 10317 | BLENDER MOUNTING KIT | |
| 15440 | BLENDER - VENTILATOR HOSE | |
| 15414 | EXHALATION VALVE DIAPHRAM REPLACEMENT KIT | |
| 3800A | BLENDER W/O HOSES | |
| NOTE - | Variety of other mountings also available. | |
| 15304 | For Military Use Only: | |
| AvianTM Transport Ventilator System | ||
| MILITARY VERSION | ||
| NSN #6530-01-374-8903 | ||
| NOTE - | Product specifications subject to change without notice. | |